7-6 Configuration
Version 2.0 Copyright © 2006 by LSI Logic Corporation. All rights reserved.
Figure 7.3 First Guided Configuration Screen
Follow these steps to create a new storage configuration in Guided
Configuration mode:
1. Select a redundancy option at the top of the Guided Configuration
window:
Redundancy Only: Create a configuration only if redundancy
(RAID 1) is possible.
Redundancy when possible: Create a redundant configuration
if possible. Otherwise, create a non-redundant configuration.
No Redundancy: Create a non-redundant configuration.
2. Choose whether you want to use existing arrays in the new virtual
disk. The options are:
Use Existing Arrays Only
Don’t Use Existing Arrays
Use Existing and New Arrays
The first and third options are disabled if there are no available
existing arrays.