Report No 088213R-ITCEP07V04
Page: 83 of 131
Test Result: Pass Source qualification: Normal
THC(A): 0.13 I-THD(%): 47.88 POHC(A): 0.002 POHC Limit(A): 0.033
Highest parameter values during test:
V_RMS (Volts): 229.74 Frequency(Hz): 50.00
I_Peak (Amps): 0.918 I_RMS (Amps): 0.387
I_Fund (Amps): 0.330 Crest Factor: 3.126
Power (Watts): 75.8 Power Factor: 0.853
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status
2 0.009
3 0.127 0.258 0.0 0.160 0.387 0.00 Pass
4 0.004
5 0.015 0.144 0.0 0.021 0.216 0.00 Pass
6 0.002
7 0.008 0.076 0.0 0.010 0.114 0.00 Pass
8 0.001
9 0.003 0.038 0.0 0.004 0.053 0.00 Pass
10 0.001
11 0.001 0.027 0.0 0.002 0.040 0.00 Pass
12 0.001
13 0.002 0.023 0.0 0.004 0.034 0.00 Pass
14 0.001
15 0.001 0.020 0.0 0.001 0.027 0.00 Pass
16 0.001
17 0.001 0.017 0.0 0.002 0.022 0.00 Pass
18 0.001
19 0.001 0.015 0.0 0.002 0.023 0.00 Pass
20 0.001
21 0.001 0.014 0.0 0.001 0.021 0.00 Pass
22 0.001
23 0.001 0.013 0.0 0.002 0.018 0.00 Pass
24 0.001
25 0.001 0.012 0.0 0.001 0.018 6.68 Pass
26 0.001
27 0.001 0.011 0.0 0.001 0.016 0.00 Pass
28 0.001
29 0.001 0.010 0.0 0.001 0.015 0.00 Pass
30 0.001
31 0.001 0.009 0.0 0.001 0.014 0.00 Pass
32 0.001
33 0.001 0.009 0.0 0.001 0.013 6.57 Pass
34 0.001
35 0.001 0.008 0.0 0.001 0.013 0.00 Pass
36 0.001
37 0.001 0.008 0.0 0.001 0.012 0.00 Pass
38 0.001
39 0.001 0.008 0.0 0.002 0.010 0.00 Pass
40 0.001
1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the
same window as the maximum harmonics/limit ratio.
2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power
>75W. Others the result should be pass.