Report No: 094061R-ITCEP07V06
Page: 76 of 123
Test Result: Pass Source qualification: Normal
THC(A): 0.00 I-THD(%): 0.00 POHC(A): 0.000 POHC Limit(A): 0.000
Highest parameter values during test:
V_RMS (Volts): 229.63 Frequency(Hz): 50.00
I_Peak (Amps): 3.548 I_RMS (Amps): 0.718
I_Fund (Amps): 0.283 Crest Factor: 5.291
Power (Watts): 65.3 Power Factor: 0.396
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status
2 0.003
3 0.264 0.222 0.0 0.263 0.333 0.00 Pass
4 0.003
5 0.254 0.124 0.0 0.253 0.186 0.00 Pass
6 0.004
7 0.240 0.065 0.0 0.240 0.098 0.00 Pass
8 0.004
9 0.222 0.033 0.0 0.222 0.049 0.00 Pass
10 0.004
11 0.202 0.023 0.0 0.202 0.034 0.00 Pass
12 0.005
13 0.179 0.020 0.0 0.180 0.029 0.00 Pass
14 0.005
15 0.156 0.017 0.0 0.157 0.025 0.00 Pass
16 0.005
17 0.133 0.015 0.0 0.133 0.022 0.00 Pass
18 0.004
19 0.110 0.013 0.0 0.111 0.020 0.00 Pass
20 0.004
21 0.088 0.012 0.0 0.090 0.018 0.00 Pass
22 0.004
23 0.069 0.011 0.0 0.070 0.016 0.00 Pass
24 0.003
25 0.052 0.010 0.0 0.053 0.015 0.00 Pass
26 0.003
27 0.038 0.009 0.0 0.039 0.014 0.00 Pass
28 0.002
29 0.027 0.009 0.0 0.028 0.013 0.00 Pass
30 0.002
31 0.020 0.008 0.0 0.020 0.012 0.00 Pass
32 0.001
33 0.015 0.008 0.0 0.015 0.011 0.00 Pass
34 0.001
35 0.013 0.007 0.0 0.013 0.011 0.00 Pass
36 0.001
37 0.012 0.007 0.0 0.012 0.010 0.00 Pass
38 0.001
39 0.012 0.006 0.0 0.011 0.010 0.00 Pass
40 0.001
1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the
same window as the maximum harmonics/limit ratio.
2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power
>75W. Others the result should be pass.